|
Vector Laboratories
antigen retrieval agent Antigen Retrieval Agent, supplied by Vector Laboratories, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pm23466670-63-15-19?v=Vector+Laboratories Average 96 stars, based on 1 article reviews
antigen retrieval agent - by Bioz Stars,
2026-07
96/100 stars
|
Buy from Supplier |
|
R&D Systems
universal antigen retrieval agent Universal Antigen Retrieval Agent, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pm16828469-95-12-17?v=R%26D+Systems Average 93 stars, based on 1 article reviews
universal antigen retrieval agent - by Bioz Stars,
2026-07
93/100 stars
|
Buy from Supplier |
|
Proteintech
antigen retrieval edta buffer Antigen Retrieval Edta Buffer, supplied by Proteintech, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pmc05392164-636-42-55?v=Proteintech Average 93 stars, based on 1 article reviews
antigen retrieval edta buffer - by Bioz Stars,
2026-07
93/100 stars
|
Buy from Supplier |
|
Thermo Fisher
citrate buffer Citrate Buffer, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pmc05010286-140-6-23?v=Thermo+Fisher Average 99 stars, based on 1 article reviews
citrate buffer - by Bioz Stars,
2026-07
99/100 stars
|
Buy from Supplier |
|
Becton Dickinson
cd20 ![]() Cd20, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pmc04804151-72-22-31?v=Becton+Dickinson Average 90 stars, based on 1 article reviews
cd20 - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Santa Cruz Biotechnology
antigen retrieval procedure ![]() Antigen Retrieval Procedure, supplied by Santa Cruz Biotechnology, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pm16868071-82-2-46?v=Santa+Cruz+Biotechnology Average 96 stars, based on 1 article reviews
antigen retrieval procedure - by Bioz Stars,
2026-07
96/100 stars
|
Buy from Supplier |
|
LSI Medience Corporation
instant antigen-retrieval agent h (neutral ![]() Instant Antigen Retrieval Agent H (Neutral, supplied by LSI Medience Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pmc04000074-66-18-23?v=LSI+Medience+Corporation Average 90 stars, based on 1 article reviews
instant antigen-retrieval agent h (neutral - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Abcam
primary mouse monoclonal antibodies against humans ![]() Primary Mouse Monoclonal Antibodies Against Humans, supplied by Abcam, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/antigen+retrieval+agent/pm31170012-39-18-25?v=Abcam Average 99 stars, based on 1 article reviews
primary mouse monoclonal antibodies against humans - by Bioz Stars,
2026-07
99/100 stars
|
Buy from Supplier |
|
VisUCyte Antigen Retrieval Reagent-Acidic
|
Buy from Supplier |
Image Search Results
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Visual heterogeneity in the intensity of CD20 staining in large B-cell lymphoma tumor tissues represented in a tissue microarray. The levels of CD20 expression is visually heterogeneous among tumor tissues (A), ranging from weak (B), intermediate (C), to strong (D) intensity of the 3,3’-diaminobenzidine (DAB) signal.
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Staining, Microarray, Expressing
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Semi-quantitative immunohistochemical scoring of CD20 expression. The images of weak and incomplete (A, upper), weak and complete (B, upper), and strong and complete (C, upper) staining for CD20 are digitally analyzed using the free web-based ImmunoMembrane (IM) plug-in that produces a combined score of 2 (A, lower), 9 (B, lower), and 20 (C, lower) in its pseudo-color image, respectively.
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Immunohistochemical staining, Expressing, Staining
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Reproducibility of the immunohistochemical scoring. The combined scores of CD20 expression obtained from the first run of semi-quantitative immunohistochemical scoring are reproducible in the second run. Yellow triangle, CD20-low group; blue triangle, CD20-high group; red rhombus, germinal center of the tonsil as control tissue.
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Immunohistochemical staining, Expressing
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Negatively skewed distribution of the combined scores of CD20 expression. The frequency histogram of the scores illustrates a wide and linear range of the semi-quantitative scores with negatively skewed distribution.
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Expressing
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: High inter- and intra-group variation in the levels of CD20 expression between patients who survived and those died. The mean of combined scores of CD20 expression was significantly lower in patients who died of disease compared to those who survived (Mann-Whitney test, * p = .012).
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Expressing, MANN-WHITNEY
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Determination of a cut-off score of CD20 expression level for poor survival outcome. Receiver operating characteristic (ROC) curve analysis was used to determine a statically optimal cut-off score of CD20 expression level for prediction of disease-associated deaths. The cut-off score of 11.75 derived from the ROC curve analysis maximized the sum of sensitivity and specificity (sensitivity, 72.7%; specificity, 70.3%; p = .012). AUC, area under the ROC curve; CI, confidence interval.
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Expressing, Derivative Assay
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Clinical and pathologic parameters in patients according to CD20 level
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques:
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Event-free survival (A) and overall survival (B) of the patients with diffuse large B-cell lymphoma according to the relative abundance of CD20 expression.
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: Expressing
Journal: Journal of Pathology and Translational Medicine
Article Title: Prognostic Implication of Semi-quantitative Immunohistochemical Assessment of CD20 Expression in Diffuse Large B-Cell Lymphoma
doi: 10.4132/jptm.2016.01.12
Figure Lengend Snippet: Univariate and multivariate analysis of clinicopathologic parameters for event-free survival and overall survival
Article Snippet: Using an automated immunohistochemical stainer (Bench-MarkXT, Ventana, Tucson, AZ, USA), sections of the TMA cut in 4-μm thickness were routinely processed for
Techniques: